EMPIAR-12953
CryoEM movies of the human mortalin(R126W)-GrpEL1(WT) complex [multiple data sets in EER format]
Publication:

Structural insights into GrpEL1-mediated nucleotide and substrate release of human mitochondrial Hsp70

Morizono MA, McGuire KL, Birouty NI, Herzik MA

Nature communications 15 (2024) 10815-10815

PMID: 39737924

Related EMDB entry:
Deposited:
2025-08-28
Released:
2025-09-17
Last modified:
2025-09-17
Imageset size:
5.11 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex - dataset 1
Category:
micrographs - multiframe
Image format:
EER
No. of images or tilt series:
952
Image size:
(4096, 4096)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(0.935, 0.935)
Details:
Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex collected on a Titan Krios G4 operating at 300 kV equipped with a Selectris-X energy filter with a 10eV slit width. All images were collected at a nominal magnification of 130,000x in EF-TEM mode (with a calibrated pixel size of 0.935 Å) on a Falcon-4 direct electron detector. Micrographs were acquired in EER format with a cumulative electron exposure of 60 electrons/Å2.

Gain file required for motion correction of unaligned micrographs for dataset 1 is included.
Files:
Loading...
2. Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex - dataset 2
Category:
micrographs - multiframe
Image format:
EER
No. of images or tilt series:
1757
Image size:
(4096, 4096)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(0.935, 0.935)
Details:
Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex collected on a Titan Krios G4 operating at 300 kV equipped with a Selectris-X energy filter with a 10eV slit width. All images were collected at a nominal magnification of 130,000x in EF-TEM mode (with a calibrated pixel size of 0.935 Å) on a Falcon-4 direct electron detector. Micrographs were acquired in EER format with a cumulative electron exposure of 60 electrons/Å2.

Gain file required for motion correction of unaligned micrographs for dataset 2 is included.
Files:
Loading...
3. Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex - dataset 3
Category:
micrographs - multiframe
Image format:
EER
No. of images or tilt series:
1861
Image size:
(4096, 4096)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(0.935, 0.935)
Details:
Unaligned multi-frame micrographs of the human mortalin(R126W)-GrpEL1(WT) complex collected on a Titan Krios G4 operating at 300 kV equipped with a Selectris-X energy filter with a 10eV slit width. All images were collected at a nominal magnification of 130,000x in EF-TEM mode (with a calibrated pixel size of 0.935 Å) on a Falcon-4 direct electron detector. Micrographs were acquired in EER format with a cumulative electron exposure of 60 electrons/Å2.

Gain file required for motion correction of unaligned micrographs for dataset 3 is included.
Files:
Loading...
Kim K, Li H, Clarke OB. (2025)
Krentzel D, Elphick M, Domart MC, Peddie CJ, Laine RF, Shand C, Henriques R, Collinson LM, Jones ML. (2025)
Arora S, Pan SH, Kumar S, Singh SK, Chauhan U, Alhalabi W, Arya V, Alsulami BS, Hsu CH, Chui KT, Gupta BB. (2025)
Costa-Gomes B, Greer J, Juraschko N, Parkhurst J, Mirecka J, Famili M, Rangel-Smith C, Strickson O, Lowe A, Basham M, Burnley T. (2025)
Zamanos A, Koromilas P, Bouritsas G, Kastritis PL, Panagakis Y. (2025)
Straub MS, Harder OF, Mowry NJ, Barrass SV, Hruby J, Drabbels M, Lorenz UJ. (2025)
Liu HF, Zhou Y, Huang Q, Martin J, Bartesaghi A. (2025)
Duraisamy AK, Fonseca N, Kleywegt GJ, Patwardhan A, Morris KL. (2025)
Lee CS, Grba DN, Wright JJ, Ivanov BS, Hirst J. (2025)
Williams HM, Curtis WA, Haubner M, Hruby J, Drabbels M, Lorenz UJ. (2025)