EMPIAR-11857
β2-adrenergic receptor in complex with GTP-bound G protein Gs, vitrified 10 seconds after addition of GTP [multiple data sets in TIFF format]
Publication:

Time-resolved cryo-EM of G-protein activation by a GPCR

Papasergi-Scott MM, Pérez-Hernández G, Batebi H, Gao Y, Eskici G, Seven AB, Panova O, Hilger D, Casiraghi C, He F, Maul L, Gmeiner P, Kobilka BK, Hildebrand PW, Skiniotis G

Nature (2024)

PMID: 38480881

Deposited:
2024-01-20
Released:
2024-06-18
Last modified:
2024-06-18
Imageset size:
13.85 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned multi-frame micrographs of β2-adrenergic receptor in complex with GTP-bound G protein Gs, vitrified 10 seconds after GTP addition (Collection 1, Grid A)
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
752
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.42605, 0.42605)
Details:
Raw unaligned movie files (tif format, 77 frames, not gain corrected).
Cryo-EM imaging of the β2AR-Gs(GTP) complex was performed on a Titan Krios electron microscope equipped with a K3 Summit direct electron detector. Super-resolution pixel size: 0.42605 Å. movies were obtained at an exposure rate of 21.13 electrons/Å^2/sec. The total exposure time was 2.717 sec over 77 frames per movie stack.
Files:
Loading...
2. Unaligned multi-frame micrographs of β2-adrenergic receptor in complex with GTP-bound G protein Gs, vitrified 10 seconds after GTP addition (Collection 1, Grid B)
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
7258
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.42605, 0.42605)
Details:
Raw unaligned movie files (tif format, 77 frames, not gain corrected).
Cryo-EM imaging of the β2AR-Gs(GTP) complex was performed on a Titan Krios electron microscope equipped with a K3 Summit direct electron detector. Super-resolution pixel size: 0.42605 Å. movies were obtained at an exposure rate of 21.13 electrons/Å^2/sec. The total exposure time was 2.717 sec over 77 frames per movie stack.
Files:
Loading...
3. Unaligned multi-frame micrographs of β2-adrenergic receptor in complex with GTP-bound G protein Gs, vitrified 10 seconds after GTP addition (Collection 2, Grid B)
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1949
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.42605, 0.42605)
Details:
Raw unaligned movie files (tif format, 77 frames, not gain corrected).
Cryo-EM imaging of the β2AR-Gs(GTP) complex was performed on a Titan Krios electron microscope equipped with a K3 Summit direct electron detector. Super-resolution pixel size: 0.42605 Å. Movies were obtained at an exposure rate of 20.95 electrons/ Å^2/sec. The total exposure time was 2.717 sec over 77 frames per movie stack.
Files:
Loading...
4. Unaligned multi-frame micrographs of β2-adrenergic receptor in complex with GTP-bound G protein Gs, vitrified 10 seconds after GTP addition (Collection 3, Grid C)
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
11456
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.42605, 0.42605)
Details:
Raw unaligned movie files (tif format, 79 frames, not gain corrected).
Cryo-EM imaging of the β2AR-Gs(GTP) complex was performed on a Titan Krios electron microscope equipped with a K3 Summit direct electron detector. Super-resolution pixel size: 0.42605 Å. Movies were obtained at an exposure rate of 30.71 electrons/Å^2/sec. The total exposure time was 2.008 sec over 79 frames per movie stack.
Files:
Loading...